One workspace for the commissioning trail

Archie reads the project's drawings, models, specifications and schedules, then computes every quantity, allowable and test pressure with a deterministic engine.

Book a demo
Archie's demo film, a walkthrough of the product. The project shown in it is a demonstration workspace.

Grouped the way the job is bought

Asset register

MSD/L02/0207

L02-0408 COMMS EQUIPMENT ROOM

Room proved byModel

The element sits inside that room on the model, never by proximity.

Drawings in, register out

Every asset harvested, placed in its room, with a basis.

Ductwork take-off

Element area

1,399.0m²

Every duct element measured once. The connected basis is a separate total and is never added to this one.

Take-off and scope gaps

Quantities measured, then specification, drawings and bill reconciled.

Governing allowable

DW/144

166.28L/s

268.2 m² × 0.620

The lower of the two standards, at 500 Pa, sealing class B.

Documents that survive review

The governing requirement named by tier, every time.

Assets on plan, level 02

A close crop of a mechanical layout drawing, centred on one asset, with every text label removed

LVR/L02/0311 computes into a room other than the one assigned.

Room checks on your sheets

Placements you check by eye, on your own layouts.

Sealed exam

Sample rate

10% by length

p3verified

Read from RIV-ITP-MECH-Rev-2.pdf, a document held back before the work started.

A sealed exam

A fifth of the register is sealed before work starts.

Deliverables

Signed

Ductwork Leakage Test Schedule

v3 locked

No edit action is offered, because none would be accepted.

Security, stated honestly

Isolation, encryption, role-gated access and a full audit trail.

Archie is not a tool your team uses. It is a member of your team.

Meet the Archie brain

Numbers with their own working

2,459

tagged assets registered on a live project

96%

of those assets placed in a room

89 of 103

held-out rooms correct

0

numbers written by a language model

Which Level 2 dampers still have no signed test record?Assistant

Which Level 2 dampers still have no signed test record?

Checked the vault, the damper register, RIV-MECH-SPEC Rev C, +1 more4 sources, 1s

Seven of the thirteen dampers on the register have no signed test record. Four of them are on Level 2:

Level 2 dampers with no signed test record. Each cell names the document it was read from.
DamperRoomTest record

MSD/L02/0221 is the one to chase first: it is not installed yet, so it blocks the RA-01 leakage test as well as its own drop test. The other three are installed and only need witnessing.

What I checked

Hover or focus a source to mark the cells it is the evidence for, or a cell to mark its sources.

Fire and Smoke Damper Register

Every number traces to a source

A value carries the document, the page or cell, and the method that produced it.

ITR Pack · Ductwork Leakage (ITR-MEC-014)

ITR pack

SA-01 · L02-0402 AHU PLANT ROOM · Rev B

Pre-test checks

0 of 6 complete

Test pressure

Sealing class

Class B, the specified class for this system. The two standards land close together and the tighter one governs.

Test particulars

Test pressure

500Pa

Design flow

4,200L/s

Design ESP

500Pa

Duct length

118.4m

Duct area

268.2m²

Min test length

11.8m

10 per cent of the run

AS allowable

210L/s

268.2 m² × 0.783

DW allowable

166.28L/s

268.2 m² × 0.620

Governing allowable (DW/144)

166.28L/s

The lower of the two, at 500 Pa, class B

Crossover area

21.5m²

Mandatory test

Yes

Result

Result withheld. 6 pre-test checks outstanding, so this record carries no verdict yet.

Sign-off

Performed by
Reviewed by
Accepted by

Illustrative figures. The pack number, system ref, room code and leakage factors are invented for this page.

The engine computes, the model reports

The deterministic engine does the arithmetic, and the language model may only report it.

Scope gap reconciliation

Scope gap register

The specification, the drawing set and the priced bill are read separately, then compared. A system that is not in all three is a gap, and a gap is worth money or a fire engineering consequence.

Systems read

12

In all three

8

Gaps

4

Show

RA-02not found in the priced bill

EA-02not found in the drawings

EA-03not found in the specification

SX-02not found in the priced bill

Specification
cl. 15.2.1
Drawings
RIV-MECH-DUCT-0001
Priced bill
Item 4.01
Specification
cl. 15.2.1
Drawings
RIV-MECH-DUCT-0002
Priced bill
Item 4.02
Specification
cl. 15.2.2
Drawings
RIV-MECH-DUCT-0006
Priced bill
Item 4.03
Specification
cl. 15.3.1
Drawings
RIV-MECH-DUCT-0003
Priced bill
Item 4.04
Specification
cl. 15.3.1
Drawings
RIV-MECH-DUCT-0007
Priced bill
Not found
Specification
cl. 15.4.1
Drawings
RIV-MECH-DUCT-0004
Priced bill
Item 4.06
Specification
cl. 15.4.2
Drawings
Not found
Priced bill
Item 4.07
Specification
Not found
Drawings
RIV-MECH-DUCT-0008
Priced bill
Item 4.08
Specification
cl. 16.1
Drawings
RIV-MECH-DUCT-0002
Priced bill
Item 4.09
Specification
cl. 16.1
Drawings
RIV-MECH-DUCT-0007
Priced bill
Not found
Specification
cl. 15.5
Drawings
RIV-MECH-DUCT-0003
Priced bill
Item 4.11
Specification
cl. 15.7
Drawings
RIV-MECH-DUCT-0006
Priced bill
Item 4.12

Showing all 12 systems. 4 of them are gaps.

A gap is reported as a gap

Where the record cannot answer, Archie says so and lists what it needs.

Ductwork take-off

Measured quantities

Criteria version riv-2026-09-a

Systems

7

Run length

629.2m

Element area

1,399.0m²

Spread between bases

80.4m²

Area basis

Every duct element is measured once. A crossover section that two systems both draw through is held against one of them only, so the total is the fabric that exists. This is the basis for a quantity.

Reading now: Element area, 1,399.0 m² across 7 systems. The other basis reads 1,479.4 m². The two are never added together.

SA Supply air

3 systems

Supply air systems with run length and surface area on the element area basis
RefLen mElement m²
SA-01L02-0402 AHU PLANT ROOM118.4268.2
SA-02L02-0410 LIFT LOBBY CIRCULATION74.9171.0
SA-03L03-0508 TENANCY OFFICE FLOOR EAST141.2322.6
SA total334.5761.8

RA Return air

2 systems

Return air systems with run length and surface area on the element area basis
RefLen mElement m²
RA-01L02-0414 MAINTENANCE STORE96.7214.9
RA-02L03-0512 TENANCY OFFICE FLOOR WEST88.1196.4
RA total184.8411.3

TA Toilet exhaust

2 systems

Toilet exhaust systems with run length and surface area on the element area basis
RefLen mElement m²
TA-31L02-0421 SANITARY CORE NORTH52.3108.7
TA-32L03-0519 SANITARY CORE SOUTH57.6117.2
TA total109.9225.9

Illustrative figures. System refs, room codes and fan families are invented for this page.

Schematics are never measured

A diagram is authoritative for how a system connects, and for nothing else.

One engine reads the project. These are the things that come out of it.

Fire and smoke damper register

Asset register

One row per damper tag, matched to its room, its system and the thing that proved the room. A tag whose room cannot be proved is printed with the room withheld.

Tags on register

13

Room proved

12

From the model

6

Withheld

1

Room proved by
Damper register. Each row gives the tag, type, size, system, room, level and the basis the room was proved on, and opens to show where that room came from.
TagRoom
L02-0408 COMMS EQUIPMENT ROOMModel
L02-0410 LIFT LOBBY CIRCULATIONModel
L02-0412 RISER 2Printed mark
L02-0412 RISER 2Printed mark
L02-0416 MCC CONTROL ROOMDrawn symbol
L02-0414 MAINTENANCE STOREModel
L02-0416 MCC CONTROL ROOMModel
L03-0508 TENANCY OFFICE FLOOR EASTPrinted mark
L03-0512 TENANCY OFFICE FLOOR WESTPrinted mark
L03-0508 TENANCY OFFICE FLOOR EASTModel
L03-0512 TENANCY OFFICE FLOOR WESTModel
L03-0516 PLANT RISER 4Drawn symbol
WithheldWithheld

Showing all 13 tags. Open a row to see where its room came from.

The register

Every row carries its room, its source and its basis.

Ductwork take-off

Measured quantities

Criteria version riv-2026-09-a

Systems

7

Run length

629.2m

Element area

1,399.0m²

Spread between bases

80.4m²

Area basis

Every duct element is measured once. A crossover section that two systems both draw through is held against one of them only, so the total is the fabric that exists. This is the basis for a quantity.

Reading now: Element area, 1,399.0 m² across 7 systems. The other basis reads 1,479.4 m². The two are never added together.

SA Supply air

3 systems

Supply air systems with run length and surface area on the element area basis
RefLen mElement m²
SA-01L02-0402 AHU PLANT ROOM118.4268.2
SA-02L02-0410 LIFT LOBBY CIRCULATION74.9171.0
SA-03L03-0508 TENANCY OFFICE FLOOR EAST141.2322.6
SA total334.5761.8

RA Return air

2 systems

Return air systems with run length and surface area on the element area basis
RefLen mElement m²
RA-01L02-0414 MAINTENANCE STORE96.7214.9
RA-02L03-0512 TENANCY OFFICE FLOOR WEST88.1196.4
RA total184.8411.3

TA Toilet exhaust

2 systems

Toilet exhaust systems with run length and surface area on the element area basis
RefLen mElement m²
TA-31L02-0421 SANITARY CORE NORTH52.3108.7
TA-32L03-0519 SANITARY CORE SOUTH57.6117.2
TA total109.9225.9

Illustrative figures. System refs, room codes and fan families are invented for this page.

Take-off

Quantities computed from the documents by rule, never by a model.

Assets on plan

Level 02

14 of 14 drawn · 3 position flags

A crop of a mechanical layout drawing showing a supply duct run with grilles and dampers above and below a central plant enclosure, with every text label removed

Hover or focus an asset to read its tag, room and the basis its position came from. Every flag on this plate sits on a basis other than the model.

3 assets computed into a room other than the one assigned.

Plan linework is a de-identified crop with every text span removed. Tags, rooms and positions are invented for this page.

Assets on plan

Every roomed asset drawn on your own layout sheets.

ITR Pack · Ductwork Leakage (ITR-MEC-014)

ITR pack

SA-01 · L02-0402 AHU PLANT ROOM · Rev B

Pre-test checks

0 of 6 complete

Test pressure

Sealing class

Class B, the specified class for this system. The two standards land close together and the tighter one governs.

Test particulars

Test pressure

500Pa

Design flow

4,200L/s

Design ESP

500Pa

Duct length

118.4m

Duct area

268.2m²

Min test length

11.8m

10 per cent of the run

AS allowable

210L/s

268.2 m² × 0.783

DW allowable

166.28L/s

268.2 m² × 0.620

Governing allowable (DW/144)

166.28L/s

The lower of the two, at 500 Pa, class B

Crossover area

21.5m²

Mandatory test

Yes

Result

Result withheld. 6 pre-test checks outstanding, so this record carries no verdict yet.

Sign-off

Performed by
Reviewed by
Accepted by

Illustrative figures. The pack number, system ref, room code and leakage factors are invented for this page.

Commissioning documents

The governing requirement chosen by tier, and the tier named.

Scope gap reconciliation

Scope gap register

The specification, the drawing set and the priced bill are read separately, then compared. A system that is not in all three is a gap, and a gap is worth money or a fire engineering consequence.

Systems read

12

In all three

8

Gaps

4

Show

RA-02not found in the priced bill

EA-02not found in the drawings

EA-03not found in the specification

SX-02not found in the priced bill

Specification
cl. 15.2.1
Drawings
RIV-MECH-DUCT-0001
Priced bill
Item 4.01
Specification
cl. 15.2.1
Drawings
RIV-MECH-DUCT-0002
Priced bill
Item 4.02
Specification
cl. 15.2.2
Drawings
RIV-MECH-DUCT-0006
Priced bill
Item 4.03
Specification
cl. 15.3.1
Drawings
RIV-MECH-DUCT-0003
Priced bill
Item 4.04
Specification
cl. 15.3.1
Drawings
RIV-MECH-DUCT-0007
Priced bill
Not found
Specification
cl. 15.4.1
Drawings
RIV-MECH-DUCT-0004
Priced bill
Item 4.06
Specification
cl. 15.4.2
Drawings
Not found
Priced bill
Item 4.07
Specification
Not found
Drawings
RIV-MECH-DUCT-0008
Priced bill
Item 4.08
Specification
cl. 16.1
Drawings
RIV-MECH-DUCT-0002
Priced bill
Item 4.09
Specification
cl. 16.1
Drawings
RIV-MECH-DUCT-0007
Priced bill
Not found
Specification
cl. 15.5
Drawings
RIV-MECH-DUCT-0003
Priced bill
Item 4.11
Specification
cl. 15.7
Drawings
RIV-MECH-DUCT-0006
Priced bill
Item 4.12

Showing all 12 systems. 4 of them are gaps.

Scope gaps

Specification, drawings and priced bill reconciled as three independent sources.

Leakage testing: what each document actually requires

5 documents, 5 columns. Cells are extractions with page citations, unverified until checked.

RIV-COMMISSIONING-PLAN-Rev-A.pdf

Duct classification
Not addressed
Test standard
AS 4254.2 referenced for leakage, AS 1668.1 for smoke controlp9verified“Leakage testing shall be carried out to AS 4254.2 and smoke control testing to AS 1668.1.”
Sample rate
Not addressed
Witness required
Independent commissioning agent to witness all hold pointsp11verified“All hold points shall be witnessed by the independent commissioning agent.”
Rectification
Not addressed

RIV-FIRE-DAMPER-SCHEDULE-Rev-A.pdf

Duct classification
Not addressed
Test standard
AS 1668.1:2015 damper drop testp1verified“Each damper shall be drop tested in accordance with AS 1668.1:2015.”
Sample rate
100% of dampersp1verified“One hundred per cent of installed dampers shall be drop tested.”
Witness required
Fire engineer to witness the first 10 dampersp2unverified“The fire engineer shall witness the first ten damper drop tests.”
Rectification
Not addressed

RIV-ITP-MECH-Rev-2.pdf

Duct classification
Class B, 500 Pap3verified“Ductwork is Class B and shall be tested at 500 Pa.”
Test standard
AS 4254.2:2012p3verified“Leakage testing to AS 4254.2:2012.”
Sample rate
10% by lengthp3verified“Ten per cent of each system by length shall be tested.”
Witness required
Hold point, Superintendent and Contractor QAp4verified“Hold point. Superintendent and Contractor QA to attend.”
Rectification
Raise NCR, re-test, close out before commissioningp4unverified“Raise a non-conformance report, re-test and close out before commissioning.”

RIV-MECH-SPEC-Rev-C.pdf

Duct classification
Class B to AS 4254.2, low pressure, 500 Pa maximump41verified“All low pressure ductwork shall be Class B to AS 4254.2 and shall not exceed 500 Pa.”
Test standard
AS 4254.2:2012 with DW/144 as the cross-checkp41verified“Leakage shall be assessed to AS 4254.2:2012, with DW/144 used as a cross-check.”
Sample rate
10% of installed length per system, minimum one test per systemp42verified“A minimum of 10 percent of the installed duct length of each system shall be tested.”
Witness required
Superintendent's representative, 5 business days noticep43unverified“The Superintendent's representative shall be given five business days notice of each test.”
Rectification
Seal, re-test the full system, not the failed section onlyp43unverified“Where a system fails, the full system shall be sealed and re-tested, not the failed section only.”

RIV-SUBCONTRACT-MECH-Rev-B.pdf

Duct classification
Adopts the specification by reference; no separate class statedp12verified“The Subcontractor adopts the specification classification by reference.”
Test standard
Not addressed
Sample rate
Priced at 10%, confirm against spec cl. 15.6.4p27unverified“Leakage testing is priced at ten per cent of installed length.”
Witness required
Not addressed
Rectification
Re-test at Subcontractor's cost, no extension of timep28verified“Re-testing after a failure is at the Subcontractor's cost and carries no extension of time.”

Drawing to schedule

One symbol on a sheet, one schedule you can defend.

Deliverables

Riverside commercial tower

Signing is the only thing that seals a record

  1. 1Draft
  2. 2Ready for review
  3. 3Signed

Schedule table · 1

Ductwork Leakage Test Schedule

v1 · generated for job RIV-MECH · 12 systems

Draft

Open. Anyone with write access can change it, and every change stays in this version.

PDF

Event trail

  • 01v1 drafted from the job record

ITR packs · 1

ITR Pack · Ductwork Leakage (ITR-MEC-014)

v2

Ready for review

Evidence · 1

Evidence Pack · Ductwork Leakage (Level 2)

v1

Draft

Illustrative record. Titles, versions, the stored hash and every event line are invented for this page.

Sign-off

Signing renders the PDF, stores its hash and locks the record.

Every document type Archie generates

Registers and schedules:

  • Mechanical asset register

  • Assets by room

  • Assets on plan

  • Damper register

  • Valve register

  • Scope gap register

  • Materials take-off

  • Bill of quantities

Tests, plans and close-out:

  • Ductwork leakage test schedule

  • Pipe pressure test schedule

  • Inspection and test plan

  • Test record forms

  • Commissioning plan

  • Method statements

  • Risk register

  • Document request list

Documents you cannot afford to leak

Put your security requirements to us and we will answer them, control by control.

Our security posture

Per-project isolation

Details

Never used to train models

Details

Encrypted in transit and at rest

Details

Signed means sealed

Details

Everything leaves a trail

Details

Role-gated access

Details